MELINEX® 359

Product Description
Melinex® 359 is a white opaque polyester film with a two side chemical pre-treatment for improved ink adhesion and laser printing.




Typical Properties
Available Thickness [Gauge]
500;    700;    1000


Property Thickness Value Units Test
OPTICAL
Gloss 45 Degrees  500 - 1000  40    ASTM D1003 
Gloss 60 Degrees  500 - 1000  45    ASTM D1003 
TLT  1000  6.0  ASTM D1003 
TLT  700  6.5  ASTM D1003 
 
PHYSICAL
C.O.F. (dynamic)  500 - 1000  0.3 - 0.4    ASTM D1894 
Density  1000  1.51  g/cc   
Density  700  1.48  g/cc   
Tensile Strength MD  500 - 1000  20,000  psi  ASTM D882A 
Tensile Strength TD  500 - 1000  25,000  psi  ASTM D882A 
Yield (nominal)  500 - 700  2,889  in˛/lb   
Yield Strength MD  500 - 1000  12,000  psi  ASTM D882A 
Yield Strength TD  500 - 1000  12,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (190°C)  500 - 1000  1.5  Unrestrained @ 190°C/5 min 
Shrinkage TD (190°C)  500 - 1000  1.5  Unrestrained @ 190°C/5 min 



Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
P.O. Box 411
Hopewell, VA 23860 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership. Teijin® and Tetoron® are registered trademarks of Teijin Limited used under license by DuPont Teijin Films U.S. Limited Partnership. Teonex® is a registered trademark of Teijin DuPont Films Japan Limited and is used under license by DuPont Teijin Films U.S. Limited Partnership.