MELINEX® ST557

Product Description
Melinex® ST557 is a slightly hazy polyester film with low shrinkage, good flatness, and excellent handling properties. Melinex® ST557 is pretreated with a unique primer on both surfaces for adhesion in special applications.




Typical Properties
Available Thickness [Gauge]
200


Property Thickness Value Units Test
ELECTRICAL
Dielectric Constant  200  2.9    ASTM D150 25°C, 100Hz 3.0 min 
Dielectric Strength  200  10  kv  ASTM D149  
Surface Resistivity  200  10^13  Ohms/sq  ASTM D257 500 V DC @ 25°C 50% RH 
Volume Resistivity  200  10^15  Ohms-cm  ASTM D257 
 
OPTICAL
TLT  200  85.5  ASTM D1003 
 
PHYSICAL
C.O.F. (static)  200  <0.5    ASTM D1894 
Flexural Strength  200  >20,000  cycles  ASTM D2176 
 
THERMAL
Coefficient of Hygroscopic Expansion  200  8x10^-6  per % RH  40% - 80% RH 
Coefficient of Thermal Expansion  200  10x10^-6  in/in/°F  68 - 122°F 
Melting Point  200  509  °F   
Shrinkage MD (150°C)  200  0.15  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  200  0.15  Unrestrained @ 150°C/30 min 



Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
P.O. Box 411
Hopewell, VA 23860 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership. Teijin® and Tetoron® are registered trademarks of Teijin Limited used under license by DuPont Teijin Films U.S. Limited Partnership. Teonex® is a registered trademark of Teijin DuPont Films Japan Limited and is used under license by DuPont Teijin Films U.S. Limited Partnership.