MELINEX® HLA

Product Description
Melinex® HLA is a clear heat stabilized polyester film. Melinex® HLA 200 gauge has no surface treatment. Melinex® HLA 300 gauge and 500 gauge have one side surface treated for ink printing.


Typical Applications
Melinex® HLA film is suitable for applications where low thermal shrinkage, low haze and smooth surface are required. It is recommended for use in Imaging, Optical, Display, Printed Electronics, Flexible Circuitry, Membrane Touch Switch (MTS), Solid-State Lighting and ITO Sputtering applications.




Typical Properties
Available Thickness [Gauge]
200;    300;    500


Property Thickness Value Units Test
OPTICAL
Haze  200  1.8  ASTM D1003 
Haze  300  ASTM D1003 
Haze  500  ASTM D1003 
TLT  200  90  ASTM D1003 
TLT  300 - 500  89  ASTM D1003 
 
PHYSICAL
C.O.F. (dynamic)  300  0.33    ASTM D1894 
C.O.F. (dynamic)  500  0.32    ASTM D1894 
C.O.F. (static)  300  0.30    ASTM D1894 
C.O.F. (static)  500  0.34    ASTM D1894 
Elongation at Break MD  200  175  ASTM D882A 
Elongation at Break MD  300  100  ASTM D882A 
Elongation at Break MD  500  200  ASTM D882A 
Elongation at Break TD  200  145  ASTM D882A 
Elongation at Break TD  300  100  ASTM D882A 
Elongation at Break TD  500  140  ASTM D882A 
Tensile Strength MD  200  34,000  psi  ASTM D882A 
Tensile Strength MD  300  27,000  psi  ASTM D882A 
Tensile Strength MD  500  27,000  psi  ASTM D882A 
Tensile Strength TD  200  37,000  psi  ASTM D882A 
Tensile Strength TD  300  33,000  psi  ASTM D882A 
Tensile Strength TD  500  33,000  psi  ASTM D882A 
 
THERMAL
Shrinkage MD (150°C)  200 - 500  < 0.1  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  200 - 500  -0.1  Unrestrained @ 150°C/30 min 



Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
P.O. Box 411
Hopewell, VA 23860 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership. Teijin® and Tetoron® are registered trademarks of Teijin Limited used under license by DuPont Teijin Films U.S. Limited Partnership. Teonex® is a registered trademark of Teijin DuPont Films Japan Limited and is used under license by DuPont Teijin Films U.S. Limited Partnership.