MYLAR® EC

Product Description
Mylar® EC films are electrical grade films designed for use in applications where improved dimensional stability is required. In addition to lower levels of shrinkage, Mylar® EC films offer outstanding durability, chemical inertness, good dielectrics, and good handling characteristics.


General Product Info
The outstanding strength, flexibility, and electrical properties of Mylar® EC films, combined with lower than normal shrinkage levels, make them especially suited for circuitry and membrane touch switch applications. The film's moisture and chemical resistance serve as a barrier to substances that could contaminate membrane touch switches.


Special Features
Slit rolls are available in the following ID and OD configuration:
  • 3" ID 9 1/2" OD
  • 3" ID 13" OD
  • 3" ID 18" OD
  • 6" ID 11" OD
  • 6" ID 14" OD
  • 6" ID 18" OD
Master rolls are available as shown in the Standard Put-Ups table. They are splice free and are available in selected widths in minimum order quantities of 35,000 lb per order with a minimum of 10,000 lb per item.


Typical Applications
The unique balance of properties offered by Mylar® EC films makes them ideal for membrane switches and flexible circuits used in a variety of consumer and industrial products, including automotive instrument clusters, computers, calculators, telephones, cameras, and appliances.


Approvals
UL 94 VTM-2 - for 200 - 500 gauge (0.05 - 0.13mm)



Typical Properties
Available Thickness [Gauge]
200;    300;    400;    500


Property Thickness Value Units Test
ELECTRICAL
Dielectric Strength  200  7.7  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Dielectric Strength  300  10.0  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Dielectric Strength  400  11.7  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
Dielectric Strength  500  13.5  kV  ASTM D149 1/4" electrode 500 V/sec 25°C in air 
 
OPTICAL
Haze  200  16  ASTM D1003 
Haze  300  20  ASTM D1003 
Haze  400  26  ASTM D1003 
Haze  500  31  ASTM D1003 
 
PHYSICAL
Elongation at Break MD  200  155  ASTM D882A 
Elongation at Break MD  300  150  ASTM D882A 
Elongation at Break MD  400  150  ASTM D882A 
Elongation at Break MD  500  160  ASTM D882A 
Elongation at Break TD  200  135  ASTM D882A 
Elongation at Break TD  300  140  ASTM D882A 
Elongation at Break TD  400  140  ASTM D882A 
Elongation at Break TD  500  160  ASTM D882A 
Tensile Strength MD  200  27  kpsi  ASTM D882A 
Tensile Strength MD  300  24  kpsi  ASTM D882A 
Tensile Strength MD  400  24  kpsi  ASTM D882A 
Tensile Strength MD  500  23  kpsi  ASTM D882A 
Tensile Strength TD  200  33  kpsi  ASTM D882A 
Tensile Strength TD  300  26  kpsi  ASTM D882A 
Tensile Strength TD  400  26  kpsi  ASTM D882A 
Tensile Strength TD  500  24  kpsi  ASTM D882A 
Yield (nominal)  200  9,900  in˛/lb   
Yield (nominal)  300  6,600  in˛/lb   
Yield (nominal)  400  5,000  in˛/lb   
Yield (nominal)  500  4,000  in˛/lb   
 
THERMAL
Shrinkage MD (150°C)  200  1.0  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  300  0.6  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  400  0.6  Unrestrained @ 150°C/30 min 
Shrinkage MD (150°C)  500  0.5  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  200  0.3  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  300  0.2  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  400  0.2  Unrestrained @ 150°C/30 min 
Shrinkage TD (150°C)  500  0.2  Unrestrained @ 150°C/30 min 



Standard Put-ups
Core I.D. (Inches) Roll O.D. (Inches) Thickness (Gauge) Length (Feet)
3 9 1/2 200 2,500
3 9 1/2 300 1,650
3 9 1/2 400 1,250
3 9 1/2 500 1,000
10 (Master roll) 200 21,950
10 (Master roll) 300 14,650
10 (Master roll) 400 10,980
10 (Master roll) 500 8,850



Contact Info
DuPont Teijin Films U.S. Limited Partnership
3600 Discovery Drive
P.O. Box 411
Hopewell, VA 23860 USA
Tel: (800) 635-4639
Fax: (804) 530-9867



Disclaimer
Note: These values are typical performance data for DuPont Teijin Films' polyester film; they are not intended to be used as design data. We believe this information is the best currently available on the subject. It is offered as a possible helpful suggestion in experimentation you may care to undertake along these lines. It is subject to revision as additional knowledge and experience is gained. DuPont Teijin Films makes no guarantee of results and assumes no obligation or liability whatsoever in connection with this information. This publication is not a license to operate under, or intended to suggest infringement of, any existing patents.

CAUTION: Do not use in medical applications involving permanent implantation in the human body (DuPont Teijin Films Medical Policy). For other medical applications, see the Medical Caution Statement. DuPont Teijin Films accepts no liability for use of it's products in medical applications not reviewed and approved by DuPont Teijin Films or for product misuse. DuPont Teijin Films supplies products to an agreed specification and does not manufacture products designed specifically for medical end use.

Melinex®, Mylar® and Melinex® STTM are registered trademarks of DuPont Teijin Films U.S. Limited Partnership. Teijin® and Tetoron® are registered trademarks of Teijin Limited used under license by DuPont Teijin Films U.S. Limited Partnership. Teonex® is a registered trademark of Teijin DuPont Films Japan Limited and is used under license by DuPont Teijin Films U.S. Limited Partnership.